5. MAINTENANCE

The amount of use and the working environment should be taken into consideration when

planning the frequency of maintenance. Careful use and preventive maintenance will help to

ensure trouble-free operation.

Daily

Daily check amount of liquid

IfIf cooling liquid has boiled, it must be replaced, because then the solution has lost

its metal coats protective effect.

Distilled water is not recommended to be used due to alga and bacterial flora which

tends to grow in it.

Daily check gaskets of welding ends and liquid hoses. Don’t use leleaking welding

ends or hoses!

Every six months

Replace cooling liquid and rinse tubes and reservoir with clean water.

Check that heat sensor is fastened with the reservoir!

Check connections of hoses and electric wires.

0ther repairs and mountings of mains connection cables should be carried out only

by an authorised electrician.

5.1. REGULAR MAINTENANCE

Kemppi service repair shops make regular maintenance according to agreement.
The major points in the maintenance procedure are listed as follows:

Cleaning of the machine

Checking of connectors and switches

Checking of electric connections

Checking of mains cable and plug

Damaged parts or parts in bad condition are replaced by new ones

Maintenance testing. Operation and performance values of the machine are checked,

and adjusted when necessary by means of test equipment.