5 adjusting welding dynamics, 6 thermostat, 7 wire feed switch – Kemppi MIG 2530 User Manual

Page 12

Advertising
background image

EN

3.5 Adjusting welding dynamics

The adjustment of MIG welding dynamics influences the properties of the welding arc and the

amount of splatter. The recommended basic setting is ‘0’. The values -> min (-1...-9) provide a

softer arc for diminishing the amount of spatter. The values -> max (1...9) provide a coarser arc,

suitable when increased arc stability is desired and when using 100% CO₂ shielding gas for

welding steel.

3.6 Thermostat

The temperature control of the machine prevents the power source from over-heating.This

means that the machine can not become damaged if loading exceeds the specified load

factor during welding. When the signal lamp indicating overheating is lit, the welding circuit

can not be activated. The lamp will turn off after a pause of about three minutes, and welding

can be started again in the usual way by pressing gun switch.

3.7 Wire feed switch

The wire feed switch will start the wire feed motor without opening the gas valve. The power

source will start up, but without providing welding power.