2.3 Serial number

The serial number of the unit is marked on the rating plate of the unit. The serial number

makes it possible to trace product manufacturing series. You might need the serial number

when placing spare parts orders or when planning maintenance.

2.4 Connection to the mains supply

The Kempact 2530 is equipped with a five metre mains cable without a plug. Installation of

the plug should be carried out only by a competent electrician. For fuse and cable sizes, see

the technical data in the end of this document.

2.5 Distribution network

All regular electrical devices without special circuits generate harmonic currents into

distribution network. High rates of harmonic current may cause losses and disturbance to

some equipment.

WARNING:

This equipment does not comply with IEC 61000-3-12. If it is connected to a public

low voltage system, it is the responsibility of the installer or user of the equipment to ensure, by

consultation with the distribution network operator if necessary, that the equipment may be

connected.

2.6 Ground cable

Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to

be welded. The contact surface of the earth clamp should always be as large as possible. Clean

the fastening surface from paint and rust. Use at least 35 mm² cables. Thinner cross-sectional

areas cause overheating of connectors.

2.7 Wire feeding mechanism components

1.

2.

3.

4.

5.

1.

Clamp screw

2.

Clamping lever

3.

Feed rolls

4.

Gun connector (Euro)

5.

Wire guides