When you switch the machine on, a green standby light switches on.

Simultaneously, the main switch indicator light switches on. If the machine

overheats or the supply voltage is too low or too high, the welding operation

automatically switches off and the yellow overheating indicator light

switches on. The light switches off when the machine is ready for operation

again. Make sure that there is enough space around the machine allowing air

to freely flow and cool the machine.

2.6.1 display in automatic mode

1

2

3

5

6

7

4

1. Sheet thickness

2. Chart for sheet thickness and arc length trimmer

3. Operating mode

4. Material

5. Shielding gas and wire diameter recommendation

6. Wire feed speed chart

7. Welding values: wire feed speed, welding voltage and welding current
Sheet thickness displays the selected welding power setting which is based

on the fillet weld’s sheet thickness in millimetres. When you adjust the

welding power according to sheet thickness, the sheet thickness in the chart

changes thinner or thicker correspondingly.
The selected operating mode and material are shown on the display. The

display also shows a recommendation as to what shielding gas and wire

diameter should be used with the material in question.
During welding, the wire feed speed chart displays the wire’s speed.
Of all the welding parameters, only filler wire feed speed is visible on the

display all the time. Welding voltage and welding current are visible on the