4.

OperaTiOn disTurbanCes

4.1

The mOsT usual OperaTiOn disTurbanCes are as FOllOWs:

arc is not ignited:

• Cable is loose or there is a bad connection.

• Electrode of torch is highly oxidized (grey). Sharpen again lengthwise. Check that post

gas time is long enough. Check ignition by using pre-gas e.g. by 4-function operation of

torch.

• There are impurities in shielding gas (moisture, air).

• Protective hose or another insulation of torch is broken and ignition spark is “escaping”

from elsewhere than from electrode of torch.

• Torch is wet.

• At low current is used too big or blunt electrode.

gas shielding is bad (weld pool “is boiling”, electrode will be oxidized)

• There are impurities in shielding gas (moisture, air).

• There are impurities in base material (rust, base coat, grease).

• On gas nozzle or housing of tightening bushing has stuck “spatter”.

• Net of gas lens is damaged.

• There is too much draught at welding place.

• Note! With gas lens equipment you get a more balanced gas flow than with normal gas

nozzle equipment.

5.

Ordering numbers

4 m

8 m

16 m

TTC 130

627013004

627013008

627013016

TTC 130F

627013104

627016008

627013116

TTC 160

627016004

627066008

627016016

TTC 160S

627016204

627016208

627016216

TTC 220

627022004

627022008

627022016

TTC 200W

627020504

627020508

627020516

TTC 250W

627025504

627025508

627025516

TTC 250WS

627025704

627025708

627025716

11

TT

C / © Kemppi O

y / 1130

Advertising
This manual is related to the following products: