PROMIG 520R, 120R / 0544 – 15

© KEMPPI OY

Control of welding dynamics R23

When you adjust welding dynamics, adjustment value -9...0...9 is shown momenta-

rily in the Voltage display which normally shows set value / welding voltage. Value

of dynamics is shown in display for approx. 3 s after adjustment.

Control of MIG welding dynamics:

With MIG welding dynamics control you can influence arc stability.
-9...-1 Softer arc decreasing spatter
0

Default setting for all wires

1...9 Harder arc maximising stability of arc during short circuit and welding of steel with 100 %

CO2 shield gas (settings 7...9).

Digital display for wire feed speed, current and voltage P21, P22, P23

/ m / min display

Display shows set value of wire feed speed switching to true value 0.0...18.0 m/min or 0.0...25.0

m/min during welding.

A display

Display shows 0 A (*no welding*) switching to true value of welding current during welding.

V display

Display shows set value of welding voltage and true value during welding.
Note! Display shows terminal voltage of power source. Depending on length and copper cross-

section of welding cables real arc voltage and display may differ. See table below.
Cable

50 mm2

70 mm2

95 mm2

Voltage loss/10 m

0,35 V/100 A 0,25 V/100 A 0,18 V/100 A

4.1.1. WELD DATA / GAS TEST

Retrieval of welding parameters to displays

Use of WELD DATA switch retrieves welding parameters, wire feed speed, welding

current, welding voltage which were used when welding was stopped last. Welding

values are indicated in display for so long you are using the WELD DATA switch,

and are stored until you press again the start switch for gun.

Testing the gas flow

A short press on switch starts flow of shielding gas. The shielding gas flows for approximately 20

seconds, or until the switch is pressed again.