Panneau de commandes ml, Ml -functiepaneel, Funktionspanel ml – Kemppi Promig 520R User Manual

Page 17: Ml control panel, Ml kontrol panel, Ml funksjonspanel, Ml funktionspanel, Ml-ohjauspaneeli

Advertising
background image

PROMIG 520R, 120R / 0544 – 17

© KEMPPI OY

MIG

1-MIG

S32

P33

R32

P32

R31

P31

S31

S34

S35

S36

R34

R33

S33

4.2. ML CONTROL PANEL

MIG basic operations

Welding method selection (S31): no function
Control mode selection (S32): local, remote
Local controls: wire feed speed/welding power/(R31), welding voltage (R32)
Controls for MIG welding dynamics (R33)
Digital displays: wire feed speed (P31), current (P32), voltage (P33)
Retrieval of last actual welding values (S33)

SYNERGIC operations

SYNERGIC mode switch S34

Normal MIG welding with independent adjustments for wire feed speed (R31)

and voltage (R32).

SYNERGIC MIG: MIG welding with parameters which are pre-set according

to filler wire (S35, S36). Welding parameters are adjusted with adjustment

potentiometers for welding power (R31) and arc length (R32).

SYNERGIC PULSEMIG: Pulsed MIG welding with parameters which are pre-set

according to filler wire (S35, S36). Welding parameters are adjusted with adjustment

potentiometers for welding power (R31) and arc length (R32).
Gun cable length compensation (R34)