INSTALLATION INSTRUCTIONS


GAS CONNECTION (Contd)

FIG 2

The appliance as supplied is for use with Natural Gas, if it is to be adapted for LPG proceed as follows:


Isolate the appliance from the electricity and gas supplies.



Remove the pan supports and burner assemblies.



Replace the injectors with the alternative type supplied.



Use the appropriate thread sealant and check for gas soundness.



Affix the self-adhesive label to the Rating Plate to amend the Gas Category.



GAS FLOW ADJUSTMENT

(see Fig 4 Page 12)

In order to adjust the minimum gas flow proceed as follows:


Ignite the burner and turn down to the minimum setting.



Remove the control knob from the gas tap.



Adjust the flow either clockwise to decrease or anti-clockwise to increase the flame. Use a

screwdriver inserted down the gas tap rod or via the screw head adjacent to the rod for models
fitted with a Flame Supervision Device.



Check that the flame is 3- 4 mm in length, bluish in colour, stable and noiseless, and does not

extinguish when changing from maximum to minimum flow.



Replace the control knob and check that all components have been reassembled correctly.


Before leaving – Check all connections for gas leaks with soap and water. DO NOT use a naked flame
for detecting leaks. Ignite all burners to ensure correct operation of gas valves, burners and ignition.
Turn gas taps to low flame position and observe stability of the flame. When satisfied with the hotplate,
please instruct the user on the correct method of operation. In case the appliance fails to operate
correctly after all checks have been carried out, refer to the authorised service provider in your area.