INSTALLATION INSTRUCTIONS


INSTRUCTIONS FOR INSTALLATION

This appliance must be installed only by authorised personnel and in accordance with manufacture’s
installation instructions, local gas fitting regulations, municipal building codes, water supply regulations,
electrical wiring regulations AS 5601/AG601- Gas Installations and any other statutory regulations.



Gas safety regulations (Installation & Use)



Kleenmaid Installation Instructions.

POSITIONING THE APPLIANCE

Combustible Surfaces – Any adjoining wall surface situated within 200mm from the edge of any
cooktop burner must be a suitable non-combustible material for a height of 150mm for the entire length
of the cooktop. Any combustible construction above the hotplate must be at least 600mm above the
top surface of the bench and no construction shall be within 450mm above the top of the burner. Allow
a 10mm minimum clearance below the hotplate.

Ventilation – Ventilation must be in accordance with AS5601/AG601 installations. In general, the
appliance should have adequate ventilation for complete combustion of gas, proper flueing and to
maintain temperature of immediate surroundings within safe limits.

PRE-COMMISSIONING THE APPLIANCE

When unpacked, check that the following parts are included with the appliance: -



Kleenmaid Instruction and Installation Book



Pan Supports



Burner

Assemblies



Adhesive sealing strip and fixing clamps & screws



 BSP Elbow & Seal



LPG conversion kit comprising of a LPG jet for each burner and a self-adhesive label for amending

Gas Category on the appliance Rating Label.


The appliance is factory set for Natural gas but can be converted to LPG (Propane) . The test point
pressure should be adjusted to 1.00 kPa for Natural Gas and 2.75 kPa for Propane, with the relevant
burners operating at maximum as in the table below.

T.P.P. (kPa)

MODEL

Natural Gas

Propane (LPG)

Burners

CH611X CH611W

1 2.75

Wok + Rapid

CH611XFF CH611WFF

1 2.75

Wok + Rapid

CH612XFF

1 2.75

Wok + Rapid

CH711XFF

1 2.75

Wok + Rapid

CH712XFF

1 2.75

Wok + Rapid

CH911XFF

1 2.75

Rapid + Semi Rapid

CH912XFF

1 2.75

Wok + Rapid

CH913XFF

1 2.75

Wok + Rapid

CH915XFF CH915AFF

1 2.75

Rapid + Semi Rapid

CH920XFF

1 2.75

Wok + Rapid

CH1200XFF

1 2.75

Wok + Rapid

Advertising