background image

14

TECHNICAL DATA


MAINTENANCE

WARNING: SERVICING SHOULD BE CARRIED OUT ONLY BY AUTHORISED PERSONNEL

During the warranty period, in case of need all service intervention should be referred back to
the Kleenmaid Service Department. Please note that intervention or repair by any unauthorised
personnel will invalidate such warranty.

Before carrying out any maintenance, disconnect the appliance from the gas and electricity
supplies.


If a gas tap becomes stiff to operate, proceed as follows:



Remove the control knobs, pan supports, burners and cooktop fixing screws & clamps.



Remove the Cooktop from the worktop and remove any underside protective covers.



Disconnect the fixings holding the tap to the fascia panel, separate the assembly, then clean the

cone and seating with a cloth dampened with solvent.



Lightly smear the cone with high temperature grease, reassemble into position and rotate a few

times. Remove the cone again and remove any excess grease making sure that the gas ducts are
not obstructed with grease.



Carefully reassemble the components and check for gas soundness.


If it becomes necessary to replace the gas tap, proceed as follows:



Disconnect the appliance as described above.



Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the fixing

screws.



When fitting a new tap, ensure that a new gasket is used.



Re-connect the gas tap, check for gas soundness and reassemble the cooktop.

TECHNICAL DATA



ELECTRICAL DETAILS

Rated Voltage 230V ac 50Hz
Supply Connection 10Amp GPO
Power Input 0.008 to 0.02kW (depending on model)
Mains supply lead 3 x 0.75mm2 Type RR-F <HAR> marked

GAS DETAILS

Connection

 ” BSP

Type

Natural Gas 1.00 kPa – ALTERNATIVE LPG 2.75 kPa


A recommended maintenance schedule is suggested to ensure your product is in optimal working