Specifications, Indoor temperature, Indoor humidity – La Crosse Technology C84612 User Manual

Page 26: Outdoor temperature, Outdoor humidity, Wind speed/ gust, Wind chill, Rainfall, Outdoor data reception interval, Air pressure

Advertising
background image

P a g e

| 26

Note: See the included Activation Card for the activation key to enable remote monitoring and

alerts.* There is no app or software to install.
All remote monitoring is done on

www.lacrossealerts.com

with an account that you create if you wish to

use these added features.*

SPECIFICAT IONS

INDOOR TEMPERATURE

41°F to 104°F (5°C to 40°C)
(“OF.L” displayed if outside this range)

INDOOR HUMIDITY

3% to 99%
(“- -” displayed if < 1%, "99" displayed if

≥ 99%)

OUTDOOR TEMPERATURE

-40°F to 139.8°F (-40°C to 59.9°C)
(“OF.L” displayed if outside this range)

OUTDOOR HUMIDITY

3% to 99%
(“- -” displayed if < 1%, "99" displayed if

≥ 99%)

W IND SPEED/ GUST

0 to 111.8 mph with resolution of 0.22 mph
0 to 180 km/h with resolution of 0.36 km/h
0 to 12 bft
0 to 97.1 knots with resolution of 0.19 knots
0 to 50 m/s with resolution of 0.1 m/s
(displays "OF.L" when > 111.62 mph; 49.9 m/s)

W IND CHILL

Down to -40°F
(displays "OF.L" if outside this)

RAINFALL

0" to 393.7" (0 to 9999 mm)
(displays "OF.L" when > 393.7")

OUTDOOR DATA RECEPTION INTERVAL

Temperature and humidity data every 13 seconds sent to the display
Wind data every 17 seconds sent to the TH sensor
Rain data every 19 seconds sent to the TH sensor

AIR PRESSURE

Relative pressure pre-set range: 27.17 to 31.90 inHg (919 to 1080 hPa)
Measured every 15 seconds

Advertising