La Crosse Technology WS-2317 User Manual

Page 40

Advertising
background image

40

With cable connection for data transmission:
Measuring interval
thermo-hygro sensor

: 8 seconds


Indoor data
Pressure/ temperature

: 4 times per minute

Indoor Temperature Range

: 14.2°F to + 139.8°F (shows

“OFL” if outside range)

Resolution

: 0.2°F

Measuring Range Rel. Humidity : 1% to 99%
Resolution

: 1%

Measuring Range Air Pressure : 8.86 inHg to 32.45 inHg

(Standard air pressure at
an altitude of 30,000 ft is
around 8.85 inHg)

Resolution

. 0.01 inHg

Relative humidity checking interval : 3 times per minute

Alarm duration

: 2 minutes (approx.)


Power consumption
Base Station
Batteries

: 3 x AA, IEC LR6, 1.5V

(Alkaline recommended)

or AC power

: INPUT 120V AC 60HZ (use

the provided AC/DC adapter
only)

Thermo-hygro sensor

: 2 x AA, IEC LR6, 1.5V (or

can draw power from the
adapter if used)


Battery life using 433MHz:

: approximately 12 months

(alkaline batteries reco


Battery life using cable connection : approximately 6 months

(alkaline batteries
recommended)

Dimensions (L x W x H):
Base Station

: 6.7 x 1.3 x 5.5 inches

Thermo-hygro sensor

: 2.8 x 2.9 x 5.4 inches

Rain sensor

: 5.5 x 2.8 x 5.4 inches

Wind sensor

: 11.5 x 2.4 x 7.8 inches

Advertising