Operating heater – Desa GWP6 User Manual

Page 13

Advertising
background image

www.desatech.com

13

117001-01A

Figure 19 - Pilot

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, page 12.

2. Make sure equipment shutoff valve is fully

open.

3. Turn off any electric power to the appliance

if service is to be performed.

4. Turn control knob clockwise

to the

OFF position.

5. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information, page 12. If you donʼt smell gas,

go to the next step.

6.

Thermostat Models:

Turn control knob

counterclockwise

to the PILOT

position. Press in control knob for five (5)

seconds.

Manual Models:

Press in and turn control

knob counterclockwise

to the PILOT

position. Keep control knob pressed in for

five (5) seconds.

7. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. Note: You may be running this

heater for the first time after hooking up to

gas supply. If so, you may need to press in

control knob for 30 seconds or more. This

will allow air to bleed from the gas system.

If needed, keep pressing ignitor button until

pilot lights. If ignitor does not light pilot,

refer to Troubleshooting, page 16 or contact

a qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 14.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 4 thru 7.

Thermostat models have a safety interlock

system. Wait one (1) minute before lighting

pilot again.

9. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Manual control heaters should

be used in locked positions.

Figure 17 - Control Knob In The OFF

Position for Manual Control Models

Figure 18 - Control Knob In The OFF

Position for Thermostat Models

OF

F

P

ILO

T

Control
Knob

Ignitor
Button

OPERATING HEATER

Continued

Ignitor Button

Control
Knob

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Thermocouple

Pilot
Burner

Ignitor Electrode

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

Advertising
This manual is related to the following products: