Product identification, Local codes, Unpacking – Desa GWP6 User Manual

Page 4: Product features, Safety information, Product identification unpacking

Advertising
background image

www.desatech.com

117001-01A

4

5. This heater needs fresh, outside air ventilation

to run properly. This heater has an Oxygen

Depletion Sensing (ODS) safety shutoff

system. The ODS shuts down the heater if

not enough fresh air is available. See Air for

Combustion and Ventilation,

page 5.

6. Keep all air openings in the front and bottom

of heater clear and free of debris. This will

insure enough air for proper combustion.

7. If heater shuts off, do not relight until you

provide fresh, outside air. If heater keeps

shutting off, have it serviced.

8. Do not run heater

• where flammable liquids or vapors are used

or stored

• under dusty conditions

9. Do not use heater if any part has been under

water. Immediately call a qualified service

technician to inspect the room heater and to

replace any part of the control system and any

gas control which has been under water.

10. Turn off heater and let cool before servicing.

Only a qualified service person should service

and repair heater.

11. Operating heater above elevations of 4,500

feet (1,371 m) could cause pilot outage.

12. To prevent performance problems, do not use

propane/LP fuel tank of less than 100 lbs.

(45 kg) capacity.

13. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If

heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

14. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use heater with care. Follow all local

codes. In the absence of local codes, use the lat-

est edition of The National Fuel Gas Code, ANSI

Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

SAFETY INFORMATION

Continued

Figure 1 - Vent-Free Gas Heater

Control Knob

Ignitor Button

Glass
Panel

Grill
Guard

Front
Panel

Heater
Cabinet

PRODUCT

IDENTIFICATION

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to

heater for shipment.

3. Check heater for any shipping damage. If

heater is damaged, promptly return to where

you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS/pilot is a required feature for vent-free room

heaters. The ODS/pilot shuts off the heater if there

is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re-

quires no matches, batteries or other sources to

light heater.

THERMOSTATIC HEAT CONTROL

(Thermostat Models Only)
Thermostat models have a thermostat sensing

bulb and a control valve. This results in the great-

est heater comfort. This can also result in lower

gas bills.

Advertising