LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the

minimum clearances shown

in Figure 4. If you can, provide

greater clearances from floor,

ceiling and joining wall.

WARNING: Never install the

heater

• in a bathroom (10,000 Btu/hr

only. 6,000 Btu/hr models are

allowed in a bathroom. Check

local codes.)

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 36"

(91.5 cm) from the front, top

or sides of the heater

• as a fireplace insert

• in high traffic areas

• in windy or drafty areas

INSTALLATION

Continued

36" (91.5 cm)

3" (7.7 cm)

FLOOR

CEILING

Minimum

6"

(15.3 cm)

Minimum

From

Sides Of

Heater

Right

Side

Left

Side

Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

CAUTION: If you install the

heater in a home garage

• heater pilot and burner must

be at least 18" (45.7 cm) above

floor

• locate heater where moving

vehicle will not hit it

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air

for Combustion and Ventilation, page 5. If high hu-

midity is experienced, a dehumidifier may be used

to help lower the water vapor content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation, inspec-

tion and service

• in coldest part of room

THERMOSTAT SENSING BULB
(Thermostat Models Only)

The thermostat sensing bulb is located inside the

heater. Do not move this bulb during installation

or operation of the heater.

INSTALLING HEATER TO WALL

Marking Screw Locations
1. Determine where you will locate heater.

WARNING: Maintain mini-

mum clearances shown in Figure

5, page 9. If you can, provide

greater clearances from floor

and joining wall.

2. Mark two mounting screw locations on wall

(see Figure 5, page 9).