Warranty information, Testing, Troubleshooting – Legrand MRHC3 User Manual

Page 5: Mrrc3 - room operating mode-a, Mrrc3 - room operating mode-b

Advertising
background image

WARRANTY INFORMATION

Manufacturer warranties its products to be free of

defects in materials and workmanship for a period

of five (5) years. There are no obligations or liabilities

on the part of manufacturer for consequential

damages arising out of, or in connection with, the

use or performance of this product or other indirect

damages with respect to loss of property, revenue or

profit, or cost of removal, installation or reinstallation.

Please

Recycle

05813r2 9/2007

Legrand Customers contact:

Vantage Customers contact:

1061 South 800 East

Orem, UT 84097

Phone: 800.555.9891

www.vantagecontrols.com

TESTING

You can test scene recall for Inputs 1 & 2 by pressing the top

button ( ) or the bottom button ( ). The LED will blink twice

indicating the command was sent.
You can recall scene 6 ( ) and scene 8 ( ) to confirm scene

bindings prior to connecting signals to Input 1 or Input 2.
External input signals can be simulated using a wire jumper

between +24VDC and Inputs 1, 2 or 3. Scene recall behavior

will be as shown in the Mode-A or Mode-B tables and the

LED will blink green twice to indicate that the input was

seen and the message was sent over the radio network.
Once the connections have been made to Inputs 1, 2 or 3 the

LED blinks twice when the input goes High or Low indicating

the input signal was received and the scene execution

message was sent out over the radio network.

TROuBLESHOOTING

During Set House ID, the LED is not flashing on some

Wireless devices.
• If LED is solid green before initiating house ID binding:

The device already has another house ID. Reset it to the

factory default so that it can be bound to the desired

house ID. Resetting to factory defaults is described in

the “I need to start over” issue.

• If LED is solid yellow after initiating house ID binding:

The device may be out of range of the initiating

device. It may be necessary to add a MRR2 Repeater if

reception to a particular area of the house is blocked.

I need to start over.

You can reset any wireless device to factory default

settings by pressing and holding until the LED

changes to solid yellow (approximately 10 seconds).

During the process, the LED flashes yellow and when

complete, it changes to solid yellow. The device can

then be reconfigured, exactly like any new device.

MRRC3 - ROOM OPERATING MODE-A

In Mode-A, inputs 1 & 2 execute their scene on the rising

edge only. No scene executes on the falling edge. Mode-

A is primarily intended for momentary control signals,

however, some maintained applications can use this feature

to provide either an Auto-On, Manual-OFF or Manual-On,

Auto-OFF control configuration.
Input 3 is intended for maintained input signals to execute a

Room-ON scene on the rising edge and a Room-OFF scene

on the falling edge, as outlined in Table 4 below.
Table 3: Default Room Mode-A

INPUT

State

Function

1

High

Room Scene 6

Low

None

2

High

Room Scene 8

Low

None

3

High

Room On Scene

Low

Room Off Scene

MRRC3 - ROOM OPERATING MODE-B

In Mode-B, input 1 and 2 are applicable to maintained inputs

only since a scene is executed on both rising and falling

edges.
Input 3 provides a scene Active/Inhibit feature. It can be

used to stop scenes from executing when a change of state

occurs on inputs 1 and 2. Input 3 can connect to a time clock

or similar device. When input 3 goes low (Scenes Active)

the controller executes the scene that corresponds to the

state of each input as if the change-of-state condition had

just occurred. When input 3 goes high (inhibit), a Room-OFF

scene is executed with the change-of-state and inputs 1 and

2 will have no effect on scenes until input 3 goes low.
Table 4: Room Mode-B

INPUT

State

Function

1

High

Room Scene 6

Low

Room Scene 7

2

High

Room Scene 8

Low

Room Scene 9

3

High

Scene Inhibit (Room-Off)

Low

Scenes Active

301 Fulling Mill Road Suite G

Middletown, PA 17057

Phone: 800.321.2343

www.legrand.us/onq

IS-0525

Advertising