ADDITIONAL GROUNDING CONNECTIONS

A grounding kit (Part No. 12001875) is available. It contains the ground wire,
clamp, ground screw and washer. Connect the ground wire to back of unit with
the cabinet ground screw and washer. Secure the other end of ground wire to a
grounded COLD metal water pipe.

NEVER CONNECT GROUND WIRE TO PLASTIC PLUMBING LINES, GAS LINES OR HOT WATER PIPES.

WATER

Water pressure of 20 to 120 p.s.i. is required to correctly fill the washer in the proper time. Pressures of less
than 20 p.s.i. may cause a failure in the water valve or the fill times to be extended past what the washer con-
trols will normally allow. The water valve may also not shut off completely.

Hot and Cold water faucets must be within 4 feet of the back of the washer for inlet hoses provided with the
washer. NOTE: Accessory inlet hoses are available in various lengths up to 10 feet for faucets more than 4
feet from the back of the washer.

TO AVOID THE POSSIBILITY OF WATER DAMAGE, SHOULD A HOSE LEAK, ALWAYS HAVE FAUCETS
ACCESSIBLE AND TURN OFF FAUCETS WHEN WASHER IS NOT IN USE.

Water heater should be set to deliver a minimum of 120° – 140° F (49° – 60° C) water to the washer.

REQUIREMENTS

ELECTRICAL

120 Volt 60 Hz 15 AMP Fuse or Circuit Breaker

Individual branch circuit serving only the washer is recommended.

The washer is equipped with a power cord.

NEVER USE AN EXTENSION CORD.

GROUNDING

ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.

Appliance is equipped with a power cord having a 3-prong grounding plug for use in a properly installed and
grounded outlet.

Improper connection of the equipment-grounding conductor can result in a risk of electrical
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether
the appliance is properly grounded. Do not modify the plug provided with the appliance – if
it will not fit the outlet, have a proper outlet installed by a qualified electrician.

IMPORTANT SAFETY PRECAUTIONS

To prevent unnecessary risk of fire, electrical shock or personal injury, all wiring and
grounding must be done in accordance with the National Electrical Code ANSI/FNPA, No.
70-Latest Revision and local codes and ordinances. It is the personal responsibility and
obligation of the appliance owner to provide adequate electrical service for this appliance.

WARNING

!