Maytag GXI6536DXS Dimension Guide User Manual

Maytag Hoods

Advertising
background image

PRODUCT MODEL NUMBERS

GXI6536DX

ELECTRICAL REQUIREMENTS

• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

VENTING REQUIREMENTS

This island hood is factory set for venting through the roof.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top of the grille. To
order, see the “Assistance or Service” section.

NOTE: Wall venting can be an option for 2-story homes.

36" (91.4 cm) Island-Mount Canopy Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10292168D

2/24/12

Non-vented (recirculating)

Roof Venting

B

A

B

A

A. Deflector
B. 6" (15.2 cm) round vent

A. Roof cap
B. 6" (15.2 cm) round vent

*Vented installations only

**Non-vented (recirculating) installations only

36" (91.4 cm)

25

³⁄₁₆"

(64.0 cm)

12¼" (31.0 cm)

13

³⁄₁₆" (33.6 cm)

*29

³⁄₄"

(75.6 cm)

min.

*44

¹³⁄₁₆"

(113.8 cm)

max.

**29

³⁄₄"

(75.6 cm)

min.

*49

¹³⁄₁₆"

(126.5 cm)

max.

3

¹⁄₂"

(8.9 cm)

Page 1 of 2

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) round

45° elbow

2.5 ft (0.8 m)

90° elbow

5.0 ft (1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

PRODUCT DIMENSIONS

Example vent system

The following example falls within the maximum vent length of 35 ft
(10.7 m).

1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight

= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)

System length

= 13.0 ft (3.9 m)

90 elbow

6 ft (1.8 m)

2 ft

(0.6 m)

Wall cap

Advertising