MEGA Corp. MMP4-2 User Manual
Page 45
 
MMP 4-2 
5 Nov 2011 
SECTION 8
Scheduled Inspections
8-4
 
 
FREQUENCY
STEP
HYDRAULIC SYSTEM
DAILY
250
Hours
500
Hours
1000
Hours
1
Check hydraulic oil for proper 
level, clarity, foaming and signs of 
contamination. 
Repair, adjust or replace as 
required. 
X
2
Check hydraulic control valve for 
security, damage, function and 
leaks. 
Repair as required. 
X
3
Check hydraulic pump for 
security, damage and leaks. 
Repair as required. 
X
4
Check hydraulic oil cooler for 
security, damage and leaks. 
Repair as required. 
X
5
Check
hydraulic
hosing
for
security, damage and leaks. 
Repair as required. 
X
6
Check hydraulic cylinders and flow 
controls for security, damage and 
leaks. 
Repair as required. 
X
7
Check hydraulic oil filter for 
security, damage and leaks. 
Repair as required 
X
8
Check
hydraulic
pressure
regulator for function and pressure 
setting (2,100 psi or 14,450 kpa). 
Adjust or repair as required. 
X
9
Drain and refill hydraulic reservoir 
and 
replace
hydraulic
filter
element.
X
10
Check
hydraulic
pump
drive
coupling for wear, security and 
damage. 
Repair as required. 
X