MANUAL LIGHTING INSTRUCTIONS

FOR ELECTRICAL POWER OUTAGE

WARNING: You must operate this heater with the

fireplace screen in place. Make sure fireplace screen
is in place before running heater.

NOTICE: During initial operation of new heater, burning
logs will give off a paper-burning smell. Open damper or
window to vent smell. This will only last a few hours.

Because this fireplace has an electronic ignition system, in the
event there is a loss of power, it will be necessary to manually
light the pilot with the piezo ignitor. After the pilot is lit, the
main burner will light automatically.

1.

Follow steps 1 through 3 under Normal Lighting Instructions,
pages 25.

2.

Set manual ignition bypass switch on control panel to ON
position (manual ignition position). See Figure 58.

3.

The pilot is attached to the rear of the front burner. You
will be able to see the pilot and spark electrode without
removing the screen or logs.

4.

Place the magnetic manual override handle, provided with
this unit, on the end of the gas valve stem (see Figure 58).

5.

Turn the override handle fully counterclockwise

to

the PILOT position. The handle will not stop but will begin
to slip when you have fully turned to the PILOT position.

6.

While holding the valve handle in the PILOT position, press
and release piezo ignitor button (see Figure 58). This will light
the pilot. If needed, keep pressing ignitor button until pilot lights.

7.

When pilot flame is lit, hold manual override handle until
thermocouple heats (approximately 5 to 15 seconds). If pi-
lot goes out, repeat process. If several attempts to light the
pilot fail, contact a qualified service person or gas supplier
for repairs.

8.

When thermocouple is heated, release override handle. The
main burner will immediately light on high flame. Adjust
flame size by turning override handle.

OPERATING FIREPLACE

Manual Lighting Instructions for Electrical Power Outage
To Turn Off Gas To Appliance
Optional Blower Operation

OPERATING FIREPLACE

Continued

ON

OFF

HI

LO

MANUAL

IGNITION

Figure 58 - Control Locations

Manual Ignition
Bypass Switch
(Down is ON)

Magnetic Manual
Override Handle

ON/OFF
Button

HI/LO
Button

Piezo Ignitor

Wall
Switch

Gas Valve

LED

LED

Locate the blower switch by opening lower louver on fireplace.
Blower switch is located at lower right inside louver door.

The GA3650T/GA3700T Series thermostat-controlled blower
has a variable speed control with an ON/OFF switch. The
blower will start when the thermostat senses a sufficient in-
crease in firebox temperature. The GA3700/GA3750 Series
variable speed blower also has an ON/OFF switch built into the
variable speed control.

Note for GA3650T/GA3700T Series Only:

If you are using

this series blower, your fireplace and blower will not turn on
and off at the same time. The fireplace may run for several
minutes before the blower turns on. After the heater modulates
to the pilot position, the blower will continue to run. The blower
will shut off after the firebox temperature decreases.

Note:

It is safe to operate fireplace with blower turned off.

However, the blower helps distribute heated air from the fireplace.

Follow installation instructions included with the blower
accessory.

OPTIONAL BLOWER OPERATION

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater When Manually Lit

Set manual ignition bypass switch on control panel to OFF
(automatic ignition position). This will cause the controls to shut
down the fireplace.