Service and replacement parts (circuits), Analog dual-cavity cabinet – Metro T-Series Hot Food Holding Cabinets User Manual

Page 18

Advertising
background image

18

SERVICE AND REPLACEMENT PARTS (CIRCUITS)

Analog Dual-Cavity Cabinet

WIRE NUT

WIRE NUT

WHITE

BLACK

BLACK 24"

10

18

BLACK 9"

BLACK 9"

BLACK 16"

BLACK 16"

BLACK 24"

13

21

7

13

21

A

13

7

B

B

4

21

10

A

4

4

TOP COMPARTMENT

BOTTOM COMPARTMENT

BOT COMPARTMENT

THERMOSTAT &

THERMOSTAT

BULBS

10

7

1

21

B

THERMAL

CUT OUT

AIR ELEMENT

10

B

21

AC BLOWER MOTOR

4

2

6

10

1

5

RED

LIGHT

THERMAL

CUT OUT

BLACK 46"

WHITE 33"

WHITE 46"

BLACK 16"

A

1

2

A

10

4

TOP COMPARTMENT

THERMOSTAT &

THERMOSTAT

BULBS

23

23

22

12

21

15

14 8

7

13

19

12

12

18

17 11

16 10

21
22

23

24

9

3

4

5

6

20

14

3

4

5

TOP COMPARTMENT

THERMOSTAT

O

TERMINAL BLOCK

AC BLOWER MOTOR

MASTER POWER

SWITCH

20

BOT. COMPARTMENT

THERMOMETER

18

2

BOT.COMPARTMENT

THERMOSTAT

BLACK 37"

WHITE 38"

WHITE 37"

BLACK 6"

BLACK 6"

BLACK 50"

BLACK 70"

-

C5T SERIES

ANALOG DUAL COMP

AR

TMENT CABINET

TOP COMPARTMENT

THERMOMETER

RED

LIGHT

6

14

20

24

22

24

6

3

AIR ELEMENT

POWER CORD

GREEN

STRAIN RELIEF

BLACK 35"

WHITE 28"

WIRE NUT

WIRE NUT

GROUND STUD

G

RED

LIGHT

23

BLACK 16"

BLACK 16"

BLACK 12"

BLACK 16"

BLACK 16"

BLACK 16"

C
C

Advertising