Operation, Continued, Curing logs – Desa BVDR18 User Manual

Page 14

Advertising
background image

www.desatech.com

901746-01E

14

OPERATION

Continued

Pilot
Burner

Thermocouple

Figure 22 - Thermocouple and Pilot

6. With control knob pressed in, push down

and release ignitor button. This will light
pilot. The pilot is attached to the rear of
the front burner. If needed, keep pressing
ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match

7. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.

Note: If pilot goes out, repeat steps 3
through 7.

8. Turn control knob counterclockwise

to the ON position. Burner should

light. If burner does not light, call a quali-
fied service person.

9. To leave pilot lit and shut off burners only,

turn control knob clockwise

to the

PILOT position.

Ignitor

Figure 21 - Ignitor and Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

ON

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

FROM "PILOT" POSITION

SLIGHT

PUSH

T

O

TURN OFF

PULL

PUSH

ON

OFF

On

Off

OFF

OFF

Control Knob

TO TURN OFF GAS

TO APPLIANCE

1. Turn control knob clockwise

to the

PILOT position.

2. Press in and turn control knob clockwise

to the OFF position.

3. Close equipment shutoff valve (see

Figure 5, page 8).

CURING

LOGS

During the 2-3 hour appliance break-in pe-
riod, you may detect an odor from appliance
as various paints and compounds used in
manufacturing of this log set cure. This is a
normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn logs in consecutive 1 hour periods

raising flame an additional 2" to full flame
height for a total of three hours.

OPERATING INSTRUCTIONS

FOR GA9050A-1

Note: Operation instructions for GA9150A
Remote Ready Valve/Pilot Kit will be included
with the kit.
1. STOP! Read the safety information,

page 13.

2. Make sure equipment shutoff valve is fully

open.

3. Press in and turn control knob clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas around log set and
near floor. If you smell gas, STOP! Refer
to the National Fuel Gas Codes, ANSI
Z233.1/NFPA 54, Air for Combustion and
Ventilation
. If you don’t smell gas, go to
the next step.

5. Turn control knob counterclockwise

to the PILOT position and press in (see
Figure 21). Keep control knob pressed in
for five (5) seconds.

Note: You may be running this log set
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

.

Advertising
This manual is related to the following products: