Installation and Gas Connection
1. Place burner pan assembly in center of

fireplace floor. Make sure inlet end of pan
faces gas supply.

2. Thread gas supply fitting to fireplace gas

supply pipe. Use thread sealant.

3. Install adapter fitting onto burner inlet fit-

ting using thread sealant on male threads
of burner inlet fitting (see Figure 6). Adjust
to most convenient position.

4. Install gas connector tube to gas supply

fitting. Carefully shape tube to attach to
adapter fitting. Be careful not to cause
kinks in tube.

INSTALLATION

Continued

5. Using thread sealant (resistant to the action

of propane/LP gas) on larger end of fitting,
screw the burner inlet fitting through hole
and into burner manifold. Tighten using
a wrench. If using propane/LP gas, see
Propane/LP Gas Conversion, page 10.

6. Using burner clamp, screw, and nut pro-

vided, assemble clamp to pan (“U” style
burners only). This will hold the burner
manifold in place.

7. If using optional GA9050A-1 kit, go to

Optional GA9050A-1 On/Off Safety
Valve/Pilot Kit Assembly
for installation
instructions. If using optional GA9150A
kit, follow instructions included with kit for
installation and operation.

Figure 8 - Installing Burner

Burner Clamp

Nut

Burner
Manifold

Burner Inlet
Fitting

Screw

Burner
Pan

Figure 9 - Installing Burner

Adaptor Fitting

Gas
Connector
Tube

Burner Pan
Assembly (Facing
Front of Fireplace)

OPTIONAL GA9050A-1 ON/
OFF SAFETY VALVE/PILOT kIT
ASSEMBLy

For additional convenience and safety, or
for propane/LP conversion, an optional ON/
OFF safety valve/pilot kit is available. See
Accessories, page 19.

WARNING: You must use a

ON/OFF safety valve/pilot kit for

propane/LP conversion.

Natural Gas Installation
1. Thread the gas control valve onto the

burner inlet fitting (see Figure 10). Use
thread sealant on the male threads of the
burner inlet fitting. Hold the burner inlet
fitting with a wrench to prevent overtight-
ening the connection to the burner. Make
sure the control rod is facing the front (see
Figure 10).

Figure 10 - Installing Gas Control Valve

Gas
Control
Valve

Control Rod

Burner Inlet
Fitting

Burner Pan
Assembly