Microsonic nano-15/CI User Manual

Ultrasonic sensors

Advertising
background image

Operating instructions

Ultrasonic sensor with one
analogue output

nano-15/CI

nano-15/CU

nano-24/CI

nano-24/CU

Product Description

The nano sensor offers a non-contact
measurement of the distance to an
object that has to be present within
the sensor’s detection zone. Depend-
ing on the set window limits, a dis-
tance-proportional analogue signal is
output.
The window limits of the analogue
output and its characteristic can be
adjusted with the Teach-in proce-
dure.
One 2-colour LED indicates operation
and the state of the analogue
output.

Sensor adjustment with Teach-in procedure

Set window

margins

Place object at position .

Connect Teach-in for about

3 s to +U

B

, until LED

flashes yellow.

LED:

Place object at position .

flashes green/yellow

Set rising/falling output

characteristic curve

Connect Teach-in for about

13 s to +U

B

, until LED

flashes green/yellow

alternately.

LED flashes:

green, green/
yellow
:
rising,
green:
falling charac-
teristic curve

Reset to factory setting

Switch off power supply.

Connect Teach-in to +U

B.

Switch on power supply.

Keep Teach-in connected to

+U

B

for about 13 s,

until LED flashes

green/yellow alternately.

Disconnect Teach-in from

+U

B

within 5 s before

switching off power supply.

Connect Teach-in for about

1 s to +U

B.

Normal operating mode

To change output charac-

teristic connect Teach-in for

about 1 s to +U

B.

Wait for about 10 s.

Normal operating mode

Safety Notes



Read the operating instructions
prior to start-up.



Connection, installation and
adjustment works should be car-
ried out by expert personnel only.



No safety component in
accordance with the EU Machine
Directive

Use for intended purpose only

nano ultrasonic sensors are used for
non-contact detection of objects.

Installation



Mount the sensor at the installa-
tion site.



Connect a connection cable to the
M12 device plug.

The assembly distances shown in fig.
2 for two or more sensors should not
be fallen below in order to avoid mu-
tual interference.

Fig. 1: Pin assignment with view onto sensor

plug and colour coding of the
microsonic connection cable

1

3

colour

+U

B

-U

B

brown

blue

4

2

I|U

Teach-in

black

white

1

2

3

4

Start-Up



Connect the power supply.



Carry out the sensor adjustment in
accordance with the diagram.

Fig.2: Assembly distances, indicating syn-

chronization

≥0,25 m

≥0.25 m

≥1.3 m

≥1.4 m

A

B

Factory Setting



Rising analogue characteristic
curve between the blind zone and
the operating range

Maintenance

microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend to clean the white
sensor surface.

Notes



Every time the power supply is
switched on, the sensor detects its
actual operating temperature and
transmits it to the internal tempe-
rature compensation. This results
in a slight correction of the ana-
logue output value after 45 se-
conds.



If the sensor was switched off for
at least 30 minutes and after po-
wer on an object is placed in the
middle of the adjusted analogue
window for 30 minutes (the ana-
logue output value is in the range
of 11 to 13 mA or 4.4 to 5.6 V) a
new adjustment of the internal
temperature compensation to the
actual mounting conditions takes
place.



The sensors of the nano family
have a blind zone. Within this
zone a distance measurement is
not possible.



In the normal operating mode, an il-
luminated yellow LED signals the ob-
ject is within the adjusted window
limits.



The sensor can be reset to its fac-
tory setting (see »Further set-
tings«).