PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

5.3

30” Wide,

Epicure™ Range

ERD30

1/2

27" (686mm)

26" (660mm)

28 1/2" (724mm)

37”

(940mm)

to

35 3/4"

(908mm)

Finished Side Panel

24 3/8" (619mm)

Rear of Control Panel/Oven Door

Face of Control Panel/Oven Door

Front Edge of Bullnose

Handle

6” (152mm) Backguard

When Backguard and

Side Panels are

removed, the overall

depth decreases

by 1" (25mm)

Accessory 3” (76mm) Side Panels

(Dacor Model No. AESP03)

1 9/16"

(40mm)

ERD30

OvERALL DImENsIONs

sIDE vIEW

Revised

07/30/08

warning

Observe all governing codes and ordinances during

planning and installation. Contact your local building

department for further information.
This appliance must be installed in accordance with the

accompanying installation instructions.

Model no.

Electrical

Circuit

required

Total

Connected

Load

gas

Type

Manifold

Pressure

Min. gas Supply

Pressure

ERD30

240 Vac,

60 Hz, 30 Amp

4.2 kW

(18 Amp)

Natural

5” Water Column

6” Water Column

ERD30LP

Liquid

Propane

10” Water Column

11” Water Column

ELEctRIcAL AND GAs

sUPPLy REqUIREmENts

nOTES:

1. when backguard is removed, the side panels must

be removed.

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.