Operation – MMD Equipment 400S-6B1 User Manual

Page 29

Advertising
background image

4. Operation

4-10

4.4.5 Gauge Indication while Operating

Minimum discharge air pressure is 58psi ( 4.0 bar ) during operation

Continuing equipment operation at a lower pressure than the above pressure may cause overheating,

since it affects the separation of lubricating oil inside the oil separator and reduces the oil flow to the

compressor air-end, resulting in temperature rise.

Make sure that RPM is higher than 1,000min

-1

at no load (or low load) operation. Long continuous

operation at the lower speed than 1,000min

-1

could cause damage to each part by vibration. When

the speed becomes lower than 1,000min

-1

, stop the machine soon.

Be sure to check at times to see if gauges or each component of the unit are properly working, or
if there is any air-leak, oil-leak, water-leak or fuel-leak etc.

During normal operation, each indication of instruments is shown in the table below. Refer to
the table for daily checks.

The above table gives standard values. They may vary slightly depending on the operating
conditions and other factors.

Emergency Lamp

Protection

device

Engine oil

pressure

Coolant

temperature

Discharge

air

temperature

Engine

speed

down

Fuel

residual

level

Monitor

Starting

Starter

switch set

to “RUN”

position

ON

n

OFF

n

OFF

1

n

OFF

n

OFF

In Operation

n

OFF

Note: ※1 When engine rises, a lamp goes on temporarily.

Warning Lamp

Indicator

Lamp

Protection

device

Charging

Engine air

filter

Compressor

air filter

Preheating

Monitor

Starting

Starter

switch set

to “RUN”

position

ON

n

OFF

n

OFF

2

ON

In Operation

n

OFF

Note: ※2 Lamp goes off after preheating completed.

Discharge air pressure

At Unloa

100 to 135psi (6.9 to 9.3 bar)

In

Operation

At Full Load

58 to 100psi (4.0 to 6.9 bar)