5 stopping procedures, Operation – MMD Equipment 400S-6B1 User Manual

Page 30

Advertising
background image

4. Operation

4-11

4.4.6 Check Clogging in Oil Separator

When the differential pressure gauge of oil separator shows

red range, replace the oil separator.(See 5.6.15)









4.5 Stopping Procedures

Close the service valve completely and operate the machine about 5 minutes, until it cools

down.

Turn the starter switch to “STOP” position to stop the engine.

Remove the key from the compressor every time when you stop the engine. Keep the key and

be careful not to lose it.

Unless all the service valves are fully closed upon stopping operation, the compressed air will be

sent in reverse direction in the hoses (pipes) connected to air tools and relieved to atmosphere
continuously through the auto-relief valve. Further, when re-starting operation next time,
compressor oil will be jetted out through service valves.

Red (replacement required)

H000477

Advertising