Infrared natural gas heater, Operating heater, Continued – Desa FAS-3B User Manual

Page 12

Advertising
background image

12

105566

INFRARED NATURAL GAS HEATER

TO SELECT

HEATING LEVEL

Slightly press in control knob and turn coun-
terclockwise

to the LOW, ME-

DIUM, or HIGH positions (see Figure 18).

IMPORTANT:

Release downward pres-

sure while turning control knob. Control
knob will lock at the desired position.

WARNING: When running

heater, set control knob at LOW,
MEDIUM, or HIGH locked posi-
tions. Never set control knob be-
tween locked positions. Poor
combustion and higher levels of
carbon monoxide may result.

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

1.

STOP! Read the safety information
page 11, column 3.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise
to the OFF position.

4.

Wait five minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation page 11, column 3. If you
don’t smell gas, go to the next step.

5.

Press in and turn control knob coun-
terclockwise

to PILOT/IGN

position. Press in control knob for
five(5) seconds (see Figure 18).

Note:

You may be running this heater

for the first time after hooking up to
gas supply. If so, you may need to press
in control knob for 30 seconds. This will
allow air to bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or supplier for repairs.

6.

Release downward pressure on con-
trol knob and turn clockwise
to OFF position.

7.

Press in control knob and turn back
to PILOT/IGN. This will cause the
piezo ignitor to spark and light the
pilot gas. If needed, repeat steps 5
through 7 until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 15 through
17. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

8 . Keep control knob pressed in for 30

seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

OPERATING
HEATER

Continued

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 17 - Pilot

LIGHTING

INSTRUCTIONS

Figure 16 - Control Knob In The OFF
Position

TO TURN OFF GAS TO

APPLIANCE

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
.

2.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Shutting Off Heater

1.

Turn control knob clockwise
to the OFF position.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

to

the PILOT/IGN position.

Figure 18 - Burner Patterns

Control

Knob

FA-3B

FA-5B

LOW

HIGH

OFF

MED

Advertising
This manual is related to the following products: