105566

INFRARED NATURAL GAS HEATER

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 22 shows a correct pilot flame pattern.
Figure 23 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 23

• turn heater off (see To Turn Off Gas to

Appliance)

• see Troubleshooting, pages 15 through 17

GRH/OV 009

GOOD PILOT

Figure 22 - Correct Pilot Flame Pattern

Thermocouple

GRH/OV 010

BAD PILOT

Thermocouple

Figure 23 - Incorrect Pilot Flame Pattern

Pilot Burner

Pilot Burner

Figure 24 - Correct Burner Flame Pattern

Bad Burner Pattern-Plaque

GRH/OV 019

Figure 25 - Incorrect Burner Flame Pattern

BURNER FLAME PATTERN

Figure 24 shows a correct burner flame
pattern. Figure 25 shows an incorrect burner
flame pattern.

If pilot flame pattern is incorrect, as shown
in Figure 25

• turn heater off (see To Turn Off Gas to

Appliance)

• see Troubleshooting, pages 15 through 17

CLEANING AND
MAINTENANCE

ODS/PILOT AND BURNER
ORIFICE

• Use a vacuum cleaner, pressurized air, or

small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.

WARNING: Turn off heater

and let cool before servicing.

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise
to the OFF position.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

to

the PILOT position.

OPERATING
HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 13.

2.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these
models differs from standard thermo-
stats. Standard thermostats simply turn
on and off the burner. The thermostat
used on this heater senses the room tem-
perature. At times the room may exceed
the set temperature. If so, the burner will
shut off. The burner will cycle back on
when room temperature drops below the
set temperature. The temperature set-
ting knob can be set to any comfort level
between 1 and 7.

Note:

The thermostat sensing bulb mea-

sures the temperature of air near the
heater cabinet. This may not always agree
with room temperature (depending on
housing construction, installation loca-
tion, room size, open air temperatures,
etc.) Frequent use of your heater will let
you determine your own comfort levels.