Owner’s manual, Operating heater, Continued – Desa FAS-3B User Manual

Page 13: For your safety read before lighting, Lighting instructions, Thermostat models fas-3b and fas-5b

Advertising
background image

13

105566

OWNER’S MANUAL

OPERATING
HEATER

Continued

THERMOSTAT MODELS FAS-3B
AND FAS-5B

FOR YOUR SAFETY

READ BEFORE

LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,
column 1.

2.

Make sure manual shutoff valve is
fully open.

3.

Push in control knob slightly and
turn clockwise

to the OFF

position. Be sure that the tempera-
ture setting knob is set at the line
between level 1 and level 7 (see Fig-
ure 19).

4.

Wait five minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column 1. If you don’t
smell gas, go to the next step.

OFF

ON

PILOT

IGN

1

7

3

5

4

6

2

Figure 19 - Dual Control for Thermostat
Models FAS-3B and FAS-5B

Continued

5.

Push in and turn control knob coun-
terclockwise

to PILOT po-

sition. Press in control knob for
five(5) seconds.

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, you may
need to press in control knob for 30
seconds. This will allow air to bleed
from the gas system.

6.

Release downward pressure on con-
trol knob and turn clockwise
to OFF position.

7.

Press in control knob and turn coun-
terclockwise

past IGN to

PILOT (see Figure 19). This will
cause the piezo ignitor to spark and
light the pilot gas. Keep control knob
depressed for 10 seconds before re-
leasing. If needed, repeat steps 5
through 7 until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 15 through
17. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure,
page 14.

8 . When pilot is lit, turn the control

knob to ON position (see Figure 21).

9.

To select desired heating level, turn
the temperature setting knob coun-
terclockwise

between 1 and

7 (see Figure 21).

Figure 20 - Pilot

Ignitor Electrode

Pilot Burner

Thermocouple

OFF

ON

PILOT

IGN

1

7

3

5

4

6

2

OFF

ON

PILOT

IGN

1

7

3

5

4

6

2

Figure 21 - Burner Patterns

Temperature

Control

Setting Knob

Knob

FAS-3B

FAS-5B

ON

OFF

Advertising