Cleaning and maintenance – Desa EFS10TNA User Manual

Page 30

Advertising
background image

www.desatech.com

112462-01G

30

ClEaNiNG aND

maiNTENaNCE

WARNING: Turn off fireplace

and let cool before cleaning.

CAUTION: You must keep con-

trol areas, burner and circulating

air passageways of fireplace clean.

Inspect these areas of fireplace

before each use. Have fireplace

inspected yearly by a qualified

service person. Fireplace may

need more frequent cleaning due

to excessive lint from carpeting,

pet hair, bedding material, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

BURNER INjECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount

of air to mix with the gas. This provides a clean

burning flame. Keep these holes clear of dust, dirt,

lint and pet hair. Clean these air inlet holes prior to

each heating season. Blocked air holes will create

soot. We recommend that you clean the unit every

three months during operation and have fireplace

inspected yearly by a qualified service person.

We also recommend that you keep the burner

tube and pilot assembly clean and free of dust and

dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you don’t follow directions on the can,

you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet

holes on injector holder for dust and dirt (see

Figure 50).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

2" from where the pilot flame comes out of the

pilot assembly (see Figures 51 or 52 depending on

model). With the unit off, lightly blow air through

the air inlet hole. You may blow through a drinking

straw if compressed air is not available.

Figure 50 - Injector Holder On Outlet

Burner Tube

Burner
Tube

Injector
Holder

Primary Air
Inlet Holes

Ports/Slots

Figure 51 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Assembly

Pilot Air
Inlet Hole

Pilot Assembly

Pilot Air
Inlet Hole

Figure 52 - Pilot Inlet Air Hole

(Natural Gas)

LOG SET

• If you remove one-piece log set for cleaning,

refer to Installing Log Set and Screen, page 23,

for placement instructions.

• Replace log set if broken or chipped (dime-sized

or larger).

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.
Exterior

Use a soft cloth dampened with a mild soap and

water mixture. Wipe the cabinet to remove dust.

Advertising