Specifications, Wiring diagram, Service hints – Desa EFS10TNA User Manual
Page 35: Technical service, Replacement parts, Specifications service hints
![background image](/manuals/78139/35/background.png)
www.desatech.com
112462-01G
35
spECiFiCaTioNs
sERViCE HiNTs
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If so, con-
tact your local natural or propane/LP gas supplier.
TECHNiCal sERViCE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department at
1-866-672-6040. When calling, please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ techni-
cal services web site at
www.desatech.com
.
REplaCEmENT paRTs
Note:
Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating Products’ Technical Service
Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products at 1-866-672-6040 for
referral information.
When calling DESA Heating Products, have ready
• model number of your fireplace
• the replacement part number
WiRiNG DiaGRam
(REMOTE-READY MODELS ONLY)
Red
Jumper Wire
White
Thermopile
Gas Control
TPTH
TH
TPTH TP
EFS10TPA, VMH10TPC
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
•
Ignition: Electronic Ignitor
• Manifold Pressure: 8.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
EFS10RPA, CGCF10PR, VMH10RPC
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
•
Ignition: Electronic Ignitor
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
* For purpose of input adjustment
EFS10TNA, VMH10TNC
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
•
Ignition: Electronic Ignitor
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
EFS10RNA, CGCF10NR, VMH10RNC
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
•
Ignition: Electronic Ignitor
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
* For purpose of input adjustment
ALL MODELS
• Dimensions (HxWxD): Fireplace (including hood and screws) - 25
7
/
8
" x 26
13
/
16
" x 9
3
/
8
",
Carton - 32
5
/
8
" x 27
13
/
16
" x 11
5
/
8
"
• Weight: Fireplace - 44.5 lbs., Shipping: 48 lbs.