CLEANING AND

MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep con-

trol areas, burners and circulating

air passageways of heater clean.

Inspect these areas of heater

before each use. Have heater

inspected yearly by a qualified

service person. Heater may need

more frequent cleaning due to

excessive lint from carpeting, pet

hair, bedding material, etc.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount

of air to mix with the gas. This provides a clean

burning flame. Keep these holes clear of dust, dirt,

lint and pet hair. Clean these air inlet holes prior to

each heating season. Blocked air holes will create

soot. We recommend that you clean the unit every

three months during operation and have heater

inspected yearly by a qualified service person.
We also recommend that you keep the burner

tube and pilot assembly clean and free of dust and

dirt. To clean these parts we recommend using

compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center

may carry compressed air in a can. You can use a

vacuum cleaner in the blow position. If using com-

pressed air in a can, please follow the directions on

the can. If you donʼt follow directions on the can,

you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow

the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet holes on

injector holder for dust and dirt (see Figure 39).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figure 40). With the unit

off, lightly blow air through the air inlet hole. You

may blow through a drinking straw if compressed

air is not available.

Burner
Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

Burner
Tube

Injector
Holder

Primary Air
Inlet Holes

Figure 39 - Injector Holder On Outlet

Burner Tube

Figure 40 - Pilot Inlet Air Hole

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs,

page 17, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the

heater running. All slotted burner flame holes should

be open with yellow flame present. All round burner

flame holes should be open with a small blue flame

present. Some burner flame holes may become

blocked by debris or rust, with no flame present. If

so, turn off heater and let cool. Remove blockage.

Blocked burner flame holes will create soot.