4.3 GPI

These outputs can be used for wiring up alarms for third party control systems. The GPI
outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI
connector is shown in figure 7.

There are two GPI inputs, one for muting output power (power goes to below safe limit) and
one for complete disable (same function as key switch, lid and software disable command).

Electrical Maximums for GPI outputs

Max current: 100mA
Max voltage: 30V


EDFA-B-C 17dBm module GPI pinning:

Figure 3: GPI Outlet

Signal

Name

Pin #

Mode

Direction

STATUS

Pin 1

Open Collector Output

LOS

Loss of input signal/power Pin 2

Open Collector Output

LOP

Loss of output
signal/power

Pin 3

Open Collector Output

TERM

Temperature out of range

Pin 4

Open Collector Output

LASER

Laser bias current out of
range

Pin 5

Open Collector Output

DIS

DISABLE (completely shut
off bias current to the
laser).

Pin 6

TTL, 0V =
active level

Input

MUTE

MUTE (output power goes
below class 1 limits).

Pin 7

TTL, 0V =
active level

Input

Ground

0 volt pin

Pin 8

0V.