3 gpi – Nevion EDFA-B-C 17dBm User Manual
Page 9
EDFA-B-C 17dBm
Rev. B
nevion.com | 9
4.3 GPI
These outputs can be used for wiring up alarms for third party control systems. The GPI
outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI
connector is shown in figure 7.
There are two GPI inputs, one for muting output power (power goes to below safe limit) and
one for complete disable (same function as key switch, lid and software disable command).
Electrical Maximums for GPI outputs
Max current: 100mA
Max voltage: 30V
EDFA-B-C 17dBm module GPI pinning:
Figure 3: GPI Outlet
Signal
Name
Pin #
Mode
Direction
STATUS
Pin 1
Open Collector Output
LOS
Loss of input signal/power Pin 2
Open Collector Output
LOP
Loss of output
signal/power
Pin 3
Open Collector Output
TERM
Temperature out of range
Pin 4
Open Collector Output
LASER
Laser bias current out of
range
Pin 5
Open Collector Output
DIS
DISABLE (completely shut
off bias current to the
laser).
Pin 6
TTL, 0V =
active level
Input
MUTE
MUTE (output power goes
below class 1 limits).
Pin 7
TTL, 0V =
active level
Input
Ground
0 volt pin
Pin 8
0V.