5 connections, 1 mounting the connector module, 5connections – Nevion 3GHD-EO-2-SFP User Manual

Page 13

Advertising
background image

3GHD-EO-2-SFP

Rev. B


nevion.com | 13

5

Connections

The 3GHD-EO-2-SFP has a dedicated connector module; 3GHD-EO-2-C1. This module is
mounted at the rear of the sub-rack. The layout of the module is shown in the figure below.

Figure 12 Connector module for 3GHD-EO-L-2-SFP

Figure 13: Fiber layout

Out1 as shown in Figure 13 will always have the lowest wavelength when CWDM
and DWDM SFP’s is installed. So if the SFP installed is a 23033 SFP-3G-EO-2-
C1xxx/C1xxx with the wavelengths 1590/1610, Out1 will be 1590 and Out2 will
be 1610.

5.1 Mounting the connector module

The details of how the connector module is mounted, is found in the user manual for the sub-
rack frame FR-2RU-10-2.

This manual is also available from our web site: