Table 1: DIP settings.

Switch # Label Function, DIP=OFF

Function, DIP=ON

Comment

1

EQ1

Bypass

Automatic cable
Equalizer

Automatic cable
Equalizer on
electrical input 1

2

EQ2

Bypass

Automatic cable
Equalizer

Automatic cable
Equalizer on
electrical input 2

3

Not used

4

Latch

Non-latching switch.
Will automatically
return to main when
input signal is ”good”

Latching switch. Must
be reset to return from
standby to main

“Sticky” switching
”good” is depending
on switch criteria in
change-over mode.

5

Main

Input 1 is main

Input 2 is main

Select’s main input to
changeover

6

Not used

7

Not used

8

OVR

GYDA control.
Configuration with
GYDA

Override GYDA
control. Configuration
with DIP switch

Select configuration
from GYDA

9

RCL1

Reclocker 1 bypass

Reclocker 1 enabled

Sets reclocker mode
for output 1

10

CHO1

Change over
disabled

Change over enabled

Enables change over
for output 1

11

SEL1

Input 1 to output 1

Input 2 to output 2

This setting are
overridden if DIP 10
(CHO1) is enabled

12

Not used

13

RCL2

Reclocker 2 bypass

Reclocker 2 enabled

Sets reclocker mode
for output 2

14

CHO2

Change over
disabled

Change over enabled

Enables change over
for output 2

15

SEL2

Input 1 to output 2

Input 2 to output 2

This setting are
overridden if DIP 14
(CHO2) is enabled

16

Not used

All DIP switches are off when pointing towards the release handle.