Description, Mounting, Input – Orion System OE338-23-XX User Manual

Page 5: Output, Page, 1 of 1

Advertising
background image




Form: ORION-OE331-21-KWH-Module-01A.doc

Page

1 of 1

Description

The OE331-21-KWH (Kilowatt Hour)
Module provides the ability to record and
display KW usage and to limit demand
on your control system. Using the Prism
Graphical Computer Front End, a status
screen displays current demand, yester-
day’s demand, and the peak demand
values and times for both. Historical logs
from the previous month and the current
month are also available and can be
downloaded for archiving via the PRISM
software interface. A running total of
power consumption is also displayed on
the status screen. This value can be
manually reset at any time allowing the
user to monitor overall power consump-
tion over long periods of time.

Analog Input #2 on the KWH Module
monitors all incoming contact closures
from a KW pulse meter (usually provided
by the utility company) and times them to
generate the current KW Demand. A
user adjustable setpoint is provided to
define what each pulse represents in
Kilowatts Per Hour. A Demand Factoring
Constant is also provided if it appears that contact bounce may be affecting the operation. The Demand Factor is
simply the number of times to average the current demand reading to create the final Demand Reading. It is nor-
mally left at a value of '1' unless a problem is encountered.

Two additional setpoints are provided for the EMS Demand Limiting Broadcast. A Limit Setpoint and a Propor-
tional Reset Range are provided so that the user can adjust when to begin shedding demand and how rapidly
this occurs. Any controllers equipped to "hear" this broadcast begin spreading their heating and cooling setpoints
proportionally until the maximum EMS Adjustment limit is reached. This value is also user adjustable for each
individual controller so that the rate at which demand is shed can be optimally configured for special cases where
not all zones can tolerate a large change in temperature.

Mounting

The KWH Module is provided with an integral backplate for mounting inside of a control enclosure. It is recom-
mended that the KWH Module be mounted in a control enclosure in the building equipment room. An optional
factory control enclosure for the KWH Module is available.

OE331-21-KWH

KWH Module



Technical Data

OE331-21-KWH

KWH Module

Power

24 Volt AC

Weight

1.5 lb.

Power Consumption

8 VA Maximum

Network Connection

RS-485

Operating Temp

10

°F to 149°F Protocol

HSI Open Protocol Token Passing

Operating Humidity

90% RH Non-Condensing

Communications

RS-485 - 9600 Baud

Input

Output

Location Type

Location

Type

AIN2

Dry Contact Closure KW

Pulse Meter (By Others)

RS-485 Communications Loop

EMS Demand Limiting

Broadcast

Three Year Warranty

WattMaster reserves the right to change specifications without notice

RL

Y

1

D1

D2

D3

D4

D5

CX

3

RAM

EPROM

C3

C2

U6

PH

IL

IP

S

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

PO

W

E

R

GND

24VAC

L1

D1

6

R6

C9

SC1

R1

1

U1

1

MC

34064

A

D1

3

C16

9936

VR2

7824C

T

M

TB4

R27

C13

R1

0

VR1

C1

9

C1

8

NE5090NPB3192

0PS

U8

CX

8

U9

X1

R7

D1

0

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXPANSION

PRESSURE

SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D1

8

D1

7

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-

5

VD

C

0-

1

VD

C

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC
AIN1
AIN2
AIN3
AIN4
AIN5

AOUT1
AOUT2

AIN7

RN

4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN

3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y

2

RL

Y

3

RL

Y

4

RL

Y

5

CX15

(1 MEG)

HH

P1

C2
1

6.2“

6.6”

7.3”

6.7”

1.1”

.20 Dia.
Typ. of 4

Advertising