When wiring to additional standard fix-

tures: Connect the sensor's red wire to the
standard light's black wires. Connect all white
wires together. Total fixture ratings must not
exceed 1000W (8.3 A).

NOTE: All wiring between fixtures should be run

in accordance with the National Electrical Code
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.

This sensor has a rating of 1000W. If your fix-

ture is only rated 300W, 700W of additional
load may be controlled by this sensor.

When determining what a fixture is rated for,

do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.

Once you have selected the fixtures to be con-

nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100W, 150W, and 75W respec-
tively, you have a total load of 325W.

(Standard)

Wiring to a Motion Light & Standard Fixture

Controlling Additional Fixtures With Your JourneyMan

®

Replacement Motion Sensor

RED from

JourneyMan

®

to

BLACK from Fixture

BLACK from Switch

to BLACK from

JourneyMan

®

WHITE from Line

to WHITE from

JourneyMan

®

WHITE from Line

to WHITE from

Fixture