User environment, Regulatory, 6powerscan – Datalogic Scanning POWERSCAN PD7100 User Manual

Page 8: Pd7100 corded

Advertising
background image

6

PowerScan

®

PD7100 Corded

Depth of Field

b

100 mil: typical 5.1" to 208.7" (13 cm to 530 cm)
55 mil: typical 1.9" to 118.1" (4.7 cm to 300 cm)
40 mil: typical 0.8" to 94.5" (2 cm to 240 cm)
20 mil: typical 0.1" to 46.9" (0.3 cm to 119 cm)
13 mil: typical 0" to 31.5" (0.1 cm to 80 cm)
10 mil: typical 0" to 23.6" (0 cm to 60 cm)
7.5 mil: typical 0.1" to 17.3" (0.2 cm to 44 cm)
5 mil: typical 0.6" to 5.5" (1.5 cm to 14 cm)

Minimum Element Width

3 mil

Print Contrast Minimum

15% minimum reflectance

Decode Capability

UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharmacode 39; Code
128; Code 128 ISBT; Code 128 add-ons; I 2 of 5; Standard 2 of 5; Code
11; Codabar; EAN 128; Code 93; DataBar Omnidirectional, DataBar
Limited, DataBar Expanded.

Interfaces Supported

RS-232 Std., RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports
5B and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard,
USB OEM, Keyboard Wedge (AT with or w/o Alternate Key, IBM AT PS2
with or w/o Alternate Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx,
34xx, 37xx make only and make break keyboard, Digital Terminals
VT2x, VT3xx, VT4xx, and Apple) and Wand Emulation.

User Environment

Operating Temperature

-22° to 122° F (-30° to 50° C)

Storage Temperature

-40° to 158° F (-40° to 70° C)

Humidity

Operating: 5% to 90% relative humidity, non-condensing
Storage: 5% to 95% relative humidity, non-condensing

Drop Specifications

50 drops from 2 meters (6.5 feet) to concrete, -30°C to 50°C

Ambient Light Immunity

Up to 100,000 LUX in sunlight.

Contaminants

Spray/rain

Dust/particulates

IEC 529-IPX5

IEC 529-IP6X

Beeper Loudness

84 dBA typical for operator at a distance of 19” (50cm)

ESD Level

25 KV

Regulatory

Electrical Safety

UL 60950, CAN/CSA-C22.2 No. 60950/IEC60950

Laser Safety

Complies with 21 CFR 1040 Class 2 and IEC/EN60825-1:2007 Class II
when laser pointer installed.

EMI/RFI

FCC Part 15 Class B, ICES-003 Class B, European Union EMC Direc-
tive

c

, Australian SMA, Taiwan EMC, Japan VCCI/MITI, Korean EMC

a.

Typical input current with factory default configuration. Max input current = 315 mA @ 5V with fac-
tory default configuration. Changes to the default (scan mode or beeper settings) may increase
the max input current up to 410 mA @ 5V and the max power up to 2.05 W.

b.

13 mil DOF based on UPC. All others are Code 39. All labels grade A, minimum illumination 300
LUX, 20°C, label inclination 10°.

c.

USB cables CAB-465, CAB-467 and CAB-486 are certified to a residential level of immunity
according to the EN 55024 and not recommended for industrial level EN61000 6-2:2005.

Item

Description