Checking the ground fault surveillance function:

When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to
light. Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for
approximately 5 seconds to ground potential, the corresponding red GROUND FAULT indicator (6) has to light and
the READY fault message relay of the INPUT MODULE NRS 90225 drops while the green READY indicator (7)
stays lit. After releasing the button, the indication and the fault message are maintained. The TEST button (3) has
to be used to reset the ground fault surveillance function. For further details on checking the function with the
REMOTE MODULE NRS 90222 being included in your installation, please refer to the PROMATRIX handbook.

9.

19"-case and 19“-rack-shelf system installation

Note

Operation of the power amplifiers DPA 4120 and DPA 4140 with enclosure cover plates detached is
strictly prohibited.

When mounting the power amplifiers within rack-cases or rack-shelf systems make sure to provide sufficient
airflow. The space between the rear panel of the amplifier and the inner wall of the rack-case has to be at least 60
mm x 330 mm. A free space of at least 100 mm above the rack-shelf system is needed to provide sufficient air
circulation. Since it is possible that during operation the temperature inside the rack system increases by 10° C, the
maximum allowable ambient temperatures of the rest of the incorporated modules and appliances within a specific
rack-shelf or rack-case have to be taken into careful consideration.

Note

To ensure trouble-free operation of the appliance, the maximum permissible ambient temperature of

+40°C is not to be exceeded.

10. Ground lift switch CIRCUIT A TO CHASSIS SWITCH
The ground lift switch CIRCUIT A TO CHASSIS SWITCH (19) provides the possibility to separate the signal ground

from the enclosure (ground potential). This is mainly meant to eliminate noise-problems which are introduced
through ground-loops, without jeopardizing the security. In case several appliances within a single rack-case or
rack-shelf are furnished with ground lift switches, it is recommended to set all devices but one to "ungrounded“. Set
one appliance to "grounded". When set to "ungrounded", the impedance between signal ground and enclosure is :
100 k ohms // 100 nF. It is needed to maintain EMV protection.

11. Fuses

11.1 Fuses in the DPA 4120
location

Pos. purpose

value

dimensions

standard

fuse socket (11)

F601 mains fuse 230V~ AC

T2A

5x20 mm

IEC 127-2-3

fuse socket (11)

F601 mains fuse 115V~ AC

T4A

5x20 mm

IEC 127-2-3

printed board assembly
86243

F602 mains fuse 100V - 250V

T1A

Ø 8.5xRM 5.08mm IEC 127-3/4

printed board assembly
85270

F502 battery fuse 24V DC

15A

flat fuse

DIN 72581-3

printed board assembly
85270

F503 battery fuse 24V DC

15A

flat fuse

DIN 72581-3

11.2 Fuses in the DPA 4140
location

Pos. purpose

value

dimensions

standard

fuse socket (11)

F601 mains fuse 230V~ AC

T4A

5x20 mm

IEC 127-2-3

fuse socket (11)

F601 mains fuse 115V~ AC

T8A

5x20 mm

IEC 127-2-3

printed board assembly
86243

F602 mains fuse 100V - 250V

T1A

Ø 8.5xRM 5.08mm IEC 127-3/4

printed board assembly
85268

F502 battery fuse 24V DC

25A

flat fuse

DIN 72581-3

printed board assembly
85268

F503 battery fuse 24V DC

25A

flat fuse

DIN 72581-3