12.2 DPA 4140 power amplifier 400 W
power supply:
mains operation

115 V / 230 V~ AC, r10 %

mains frequency

50 - 60 Hz

security class

I

mains operation

Umains / V Imains / A Pmains / VA Pmains / W

Pout / W

Pv / W

idling

230

0.19

44

23

0

23

normal operation (-10 dB)

230

1.60

368

263

40

223

alarm (-3 dB)

230

3.10

713

562

200

362

standard conditions

230

4.43

1019

811

400

411

initial current inrush (mains)

< 36 A

mains operation

Umains / V Imains / A Pmains / VA Pmains / W Pout / W

Pv / W

idling

115

0.38

44

23

0

23

normal operation (-10 dB)

115

3.19

368

263

40

223

alarm (-3 dB)

115

6.20

713

562

200

362

standard conditions

115

8.86

1019

811

400

411

initial current inrush (mains)

< 21 A

Pmains / VA = apparent power Umains*Imains; Pmains / W = true power; Pout / W = output power; Pv / W =leakage power

battery operation

24 V DC, -10/+30 %

battery operation

UB / V

IB / A

Pi / W

Pout / W

Pv / W

stand-by

24

2.5m

60m

0

60m

idling

24

0.62

15

0

15

normal operation (-10 dB)

24

7.1

170

40

130

standard conditions

24

17.3

415

249

166

initial current inrush (battery)

< 3.8 A

Pi / W = input power UB*IB; Pout / W = output power; Pv / W = leakage power

features of the input: electronically

balanced

nominal input level

775 mV = 0 dBu

nominal input impedance

t 10 k ohms

features of the power output: balanced,

floating

nominal output capacity during mains operation

400 W (according to IEC 268-3)

nominal load impedance

25 ohms / 100V; 12.5 ohms / 70 V; 6.25 ohms /
50 V or 4 ohms / 40 V

frequency response

60 Hz .. 20 kHz

distortion at 1 kHz and nominal output power

d 1 %

interfering voltage (A)

d 1.2 mV = -56 dBu

features of the monitor output: electronically

balanced

nominal output voltage

2 V = + 8.2 dBu

nominal load impedance

600 ohms

ambient temperature range

+5 °C .. +40 °C

dimensions (W x H x D)

483 x 132 x 345 mm

depth with / without connections

max. 400 mm / 340 mm

weight without extensions

16.7 kg

finish

anthracite

extension kits for the DPA 4120 and DPA 4140:

NRS 90208 input transformer for floating, balanced input

Art. No. 121 641

NRS 90222 remote module

Art. No. 121 674

NRS 90224 pilot tone & ground fault surveillance

Art. No. 121 676

NRS 90225 standard input module

Art. No. 121 677

NRS 90227 output transformer for floating, balanced monitor output

Art. No. 121 679

Advertising
This manual is related to the following products: