Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series

Revision January, 2008, Doc. Name: 2007PDD23000007

1-131

Vigor M Series

Back to Table

A. HMI factory settings

Baud rate: 19200, 7, EVEN, 1.

Controller station number: 0.

Control area/status area: D0 / D10.

NOTE

1) Controller station number: 0 for PROGRAMMER PORT; 1 for COM PORT

2) VB series also can use this driver.

B. Definition of controller Read/Write address

Registers

Read/Write Range

Register Type

Format

Word No.

Bit No.

Data length

Input Relay

Xn

n: 0 ~ 770 (Octal)

N/A

Word (multiple of 8)

Output Relay

Yn

n: 0 ~ 770 (Octal)

N/A

Word (multiple of 8)

Auxiliary Relay

Mn

n: 0 ~ 5112

N/A

Word (multiple of 8)

Special Relay

Mn

n: 9000 ~ 9248

N/A

Word (9000 + multiple
of 8)

Step Relay

Sn

n: 0 ~ 992

N/A

Word (multiple of 8)

Timer Present Value

Tn

n: 0 ~ 255

N/A

Word

16-bit Counter Present Value Cn

n: 0 ~ 199

N/A

Word

32-bit Counter Present Value Cn

n: 200 ~ 255

N/A

Word

Data Register

Dn

n: 0 ~ 8191

N/A

Word

Special Data Register

Dn

n: 9000 ~ 9248

N/A

Word

Contacts

Read/Write range

Contact type

Format

Word No.

Bit No.

Input Relay

Xn

N/A

n: 0 ~ 777(Octal)

Output Relay

Yn

N/A

n: 0 ~ 777(Octal)

Auxiliary Relay

Mn

N/A

n: 0 ~ 5119

Special Relay

Mn

N/A

n: 9000 ~ 9255

Step Relay

Sn

N/A

n: 0 ~ 999

Timer Contact

Tn

N/A

n: 0 ~ 255

Counter Contact

Cn

N/A

n: 0 ~ 255

Timer Coil

TCn

N/A

n: 0 ~ 255

Counter Coil

CCn

N/A

n: 0 ~ 255