SERVICE SPECIFICATIONS: CME1000A

When servicing a machine, it’s helpful to compare
that unit’s operating characteristics to those of a
new, clean, normally operating machine. What
follows is that type of information:

Numbers = Cabinet Air Temp/Water Temp.

Typical Batch Weight

••

8.25 - 9 lb.

Refrigerant Charge

••

42 ounces of R-404A.

Hi Pressure Cut Out Point

••

450 PSIG

Hi Temperature Cut Out Point

••

140

o

F.

Typical Compressor Amp Draw

••

90/70: 5 min. into freeze - 11.5, harvest -13.3

••

70/50: 5 min. into freeze - 10.7, harvest -11.8

Compressor:

••

CS18K6E

Water Inlet Valve Flow Rate:

••

.75 g.p.m.

Cube Size Thermostat:

••

Cut in adjustable between 0

o

F. and 24

o

F.

Bin Thermostat:

••

CI= 38.5

o

F. to 43.5

o

F.

••

CO= 33.5

o

F. to 38.5

o

F.

Thermostatic Expansion Valve

••

Not adjustable

70/50

90/70

Typical Cycle Time

11 - 12 minutes

13 - 14 minutes

Harvest Time (2

2

3

minute

standard)

2

2

3

minutes

2 minutes

Typical Freeze Cycle Low Side
Pressure (end of cycle)

25 PSIG

25 PSIG

Typical Freeze Cycle Discharge
Pressure (end of cycle)

190 PSIG

240 PSIG

Typical Harvest Cycle Low Side
Pressure (peak)

84 PSIG

94 PSIG

Typical Harvest Cycle Discharge
Pressure (min)

155 PSIG

190 PSIG