SPECIFICATIONS

Always refer to the nameplate, located on the back
of the cabinet, for the:

••

model number,

••

serial number,

••

basic electrical
requirements,

••

minimum circuit ampacity,

••

maximum fuse size,

••

and refrigerant charge.

A serial number plate with the model number,
serial number and refrigerant charge is located
behind the front panel, near the control box.

The unit comes from the factory with the correct
refrigerant charge. The refrigerant charge
information is for recharging, should that be
necessary.

All utility connections are made at the back of the
ice maker.

Before beginning installation, be sure that all of the
components necessary for complete assembly of
the ice system are available, and are the correct
components with regard to model, voltage, and
finish.

The CME855 or CME1000 will fit Scotsman bin
BH800 without needing a bin top. Other bins will
require a bin top.

Model Number

Dimensions
W" x D" x H"

Basic Electrical Refrigerant

Type

Min.
Circ.
Amps

Max.
Fuse** Size

Refrigerant
Charge*

CME855AE-32A

42 x 24 x 27

208-230/60/1

R-404A

15.9

20

36 ounces

CME855AE-6A

42 x 24 x 27

230/50/1

R-404A

36 ounces

CME1000AE-32A

42 x 24 x 27

208-230/60/1

R-404A

19.9

20

42 ounces

CME1000AE-3A

42 x 24 x 27

208-230/60/3

R-404A

13.8

15

42 ounces

CME1000AE-6A

42 x 24 x 27

230/50/1

R-404A

42 ounces

* The system charge is in the machine. This number is for recharging purposes only. If the nameplate has a
different value, go by the nameplate. ** Or HACR type circuit breakers.

Air Temperature

Water Temperature

Voltage

Minimum

50

0

F.

40

0

F.

-5%

Maximum

100

0

F.

100

0

F.

+10%