STACKING TWO CME 42" AIR COOLED

STACKING TWO UNITS

To stack a 42" wide CME cuber onto a CME855A,
CME1000A, CM855 or CM1000 cuber:

A Heavy Duty Leg Kit is Recommended.

1. Remove the top panel from the lower unit.

2. Add a bead of food grade sealant (such as
Scotsman part number 19-0529-01) to the top
edges of the lower unit’s freezing compartment.

3. Lift the top unit onto the bottom machine (a
mechanical lift is recommended).

4. Align the two machine’s cabinets, and using the
bolts and straps from the hardware package,
fasten the two units together at the back.

Note: When placing a new unit on a CM855 or
CM1000, the outboard (right side viewed from the
back) threaded holes should be used.

5. Route the bin thermostat capillary tube from the
upper machine into the lower machine and into the
bin thermostat bracket, next to the capillary tube
from the lower machine.