Portable forced air heaters, Service procedures, Continued – Desa NTH100 User Manual

Page 10

Advertising
background image

10

104976

PORTABLE FORCED AIR HEATERS

Air Output, Air Intake, and Lint
Filters

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters

Pump Pressure Adjustment

1.

Remove pressure gauge plug from filter
end cover.

2.

Install accessory pressure gauge (part
number HA1180).

3.

Start heater (see Operation, page 5).
Allow motor to reach full speed.

4.

Adjust pressure. Turn relief valve to
right to increase pressure. Turn relief
valve to left to decrease pressure. See
specifications below for correct pres-
sure for each model.

5.

Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.

Figure 16 - Air Output, Air Intake, and Lint Filters, 35/50/70,000 Btu/Hr Models

Figure 18 - Pressure Gauge Plug Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 19 - Adjusting Pump Pressure

Pump
Pressure

Model

(PSI/Bar)

35,000 Btu/Hr

2.9/0.200

50,000 Btu/Hr

4.9/0.338

70,000 Btu/Hr

5.2/0.359

100,000 Btu/Hr

3.9/0.269

150,000 Btu/Hr

4.8/0.331

(35/50/70,000 Btu/Hr Models Shown)

Relief
Valve

SERVICE
PROCEDURES

Continued

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Air Intake Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 17 - Air Output, Air Intake, and Lint Filters, 100/150,000 Btu/Hr Models

Fan Guard

Advertising