Owner’s manual, Specifications, Service procedures – Desa NTH100 User Manual

Page 13: Wiring diagrams, Continued

Advertising
background image

13

104976

OWNER’S MANUAL

Fan

IMPORTANT:

Remove fan from motor

shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.

1.

Remove upper shell (see page 8).

2.

Use 1/8" allen wrench to loosen set-
screw which holds fan to motor shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using a soft cloth moistened
with kerosene or solvent.

5.

Dry fan thoroughly.

6.

Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 30).

7.

Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds/
4.5-5.6 n-m).

8.

Replace fan guard and upper shell.

Motor
Shaft

Setscrew

Figure 29 - Fan, Motor Shaft, and Setscrew
Location

Motor
Shaft

Fan

Setscrew

Figure 30 - Fan Cross Section

Output Rating (Btu/Hr)

35,000

50,000

70,000

100,000

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity
(U.S. Gal./Liters)

3.0/11.4

5.0/18.9

5.0/18.9

9.0/34

13.5/51.1

Fuel Consumption
(Gal. Per Hr./
Liters Per Hr.)

.26/1.0

.37/1.40

.49/1.85

.70/2.7

1.1/4.1

Electric Requirements

230 V/50 Hz (Same All Models)

Amperage (Normal Run)

.8

1.0

1.0

1.2

1.2

Hot Air Output
(CFM/CMM)

140/4

205/5.8

225/6.4

425/12

500/14.2

RPM

1425

2850

2850

2850

2850

SPECIFICATIONS

Fan

Flush

SERVICE
PROCEDURES

Continued

WIRING DIAGRAMS

Figure 31 - Wiring Diagram

R

B

C

D

A

B

1

1a

230 V~/50 Hz

Green-Yellow

Green-Yellow

Ignitor

Photocell

Spark

Plug

Flame-Out

Control

Reset

Button

White

White

White

Orange

Motor

Red

Red

Red

Brown

Black

Black

Black

Blue

White

Blue

RFI Filter

ON/Off Switch

Terminal

Board

Advertising
This manual is related to the following products: