Venting inStallatiOn

Continued

10 FOOT RULE

All flue gas outlet chimney terminations must
extend a minimum of 3 feet in height above the
highest point where it passes through the roof
and must be at least 2 feet above the high-
est point of the roof that is within a horizontal
distance of 10 feet (see Figure 20).

FINISHING FIREPLACE

Combustible materials, such as wallboard,
gypsum board, sheet rock, drywall, plywood,
etc. may make direct contact with sides and top
around the fireplace face. It is important that
combustible materials do not overlap the face
itself. Brick, glass, tile or other noncombustible
materials may overlap the front face provided
they do not obstruct essential openings like
louvered slots or any other opening. When
overlapping with a noncombustible facing
material, use only noncombustible mortar or
adhesive.

24" Min.

24" Min.

18"

Min.
Typ.

Figure 19 - Multiple Chase Installation

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of
Flue Gas
Outlet

Figure 20 - 10 Foot Rule

Terminations/Spark Arrestor
The fireplace system must be terminated with
the listed round top or chase terminations. In
any case, refer to the installation instructions
supplied with the termination.

CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions

provided with the termination

being used.

Secure
Termination
to Outer
Pipe with 3
Screws

RTL-10D

Level of
Flue Gas
Outlet

Stainless
Inner Flue
Pipe

Waterproof
Caulking

Storm
Collar

Flashing

Underlap
Shingles

Figure 18 - Termination

Overlap
Shingles (Top
and Sides of
Flashing Base)

CHASE INSTALLATIONS

Instructions for chase installations are
included with the chase style termination
chosen. In a multiple chase installation, be
sure to provide adequate distance between
terminations to prevent smoke spillage from
one termination to another. We suggest that
terminations be separated at least 24", center
to center and stacked at a vertical height dif-
ference of 18" (see Figure 19).
Note: If a decorative shroud is to be installed,
contact the manufacturer for specifications.