Roubleshooting – Skutt EnviroVent 2 User Manual

Page 13

Advertising
background image

13

13

t

roublEShooting

p

roblem

: V

enT

n

oT

o

peraTIng

Possible Cause: No Power to the vent.

Solutions:

Check to see the vent is plugged in.

Check to make sure the in-line switch is on.

Check the power to the outlet. If there is no power to the outlet, check the circuit breaker.

p

roblem

: s

mell

or

odor

ComIng

from

kIln

area

Possible Cause: Air is not being pulled through the kiln slab.

Solutions:

Check to see that the holes are correctly drilled in the kiln slab.

Check to see that the holes are not blocked by debris in the chamber or a shelf placed on the slab.

Check to see that the plenum cup is aligned with the holes.

Check to see if there are holes or poor connections in the ducting.

Check to see if the exit duct is free of debris and has a clear passage to the outside.

p

roblem

: k

Iln

slow

To

reaCh

TemperaTure

Possible Cause: Too much air is being pulled into the kiln chamber.

Solutions:

Check to see the holes in the lid and slab are drilled to specification.

Check to see if the lid is closed during firing.

Check to see the all the peep plugs are in place.

p

roblem

: d

uCTIng

Is

geTTIng

Too

hoT

Possible Cause: Holes in slab are too large.

Solutions:

Check to see the holes in the slab are drilled to specification.

p

roblem

: m

oTor

Is

VIbraTIng

Possible Cause: Squirrel cage in motor is imbalanced by debris sucked into the motor.

Solutions:

Blow out motor with compressed air. Be sure to clean area around motor intake.

Check all mounting screws to see if they are secure.

For all other problems contact your Skutt Distributor.

T

roubleshooTIng

Advertising