Ventilation, Operation, Theory of operation – Desa BY150ECB 150,000 Btu/Hr 110v/50 Hz User Manual

Page 4: Fuels

Advertising
background image

4

104001

PORTABLE FORCED AIR HEATER

MODEL BY150ECB 150,000 Btu/Hr

VENTILATION

WARNING: Follow the mini-

mum fresh, outside air ventila-
tion requirements. If proper fresh,
outside air ventilation is not pro-
vided, carbon monoxide poison-
ing can occur. Provide proper
fresh, outside air ventilation be-
fore running heater.

OPERATION

WARNING: Review and un-

derstand the warnings in the
Safety Information Section, pages
2 and 3. They are needed to safely
operate this heater. Follow all lo-
cal codes when using this heater.

TO START HEATER

1.

Follow all ventilation and safety infor-
mation.

2.

Fill fuel tank with kerosene or No. 1
fuel oil.

3.

Attach fuel cap.

4.

Plug power cord of heater into standard
110 volt/50 hertz, grounded (earthed)
outlet. Use an extension cord if needed.
Use only a three-prong, grounded
(earthed) extension cord.

Provide a fresh air opening of at least 2800
square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.

Example:

A 150,000 Btu/Hr heater re-

quires one of the following:

a two-car garage door raised 15 cm
(six inches)

a single-car garage door raised
23 cm (nine inches)

two, 76 cm (thirty-inch) windows
raised 31 cm (twelve inches)

THEORY OF
OPERATION

The Fuel System:

The air pump forces

air through the air line. The air is then
pushed through the burner head nozzle.
This air causes fuel to lift from the tank. A
fine mist of fuel is sprayed into the combus-
tion chamber.

The Air System:

The motor turns the

fan. The fan pushes air into and around the
combustion chamber. This air is heated
and provides a stream of clean, hot air.

The Ignition System:

The electronic

ignitor sends voltage to the spark plug. The
spark plug ignites the fuel and air mixture.

The Flame-Out Control System:

This

system causes the heater to shut down if the
flame goes out.

THEORY CUTAWAY

PFA/OV 003

Fuel Filter

Air For Fuel
System

Air For Combustion
And Heating

Fuel

Combustion
Chamber

Air Intake
Filter

Clean
Heated
Air
Out

Cool
Air
In

Air
Output
Filter

Fuel
Tank

Figure 3 - Cross Section Operational View

Burner
Head

Spark
Plug

Motor

Fan

Electronic
Ignitor

Air Line
To Burner

Nozzle

Air Pump

FUELS

WARNING: Use only kerosene

or No. 1 fuel oil to avoid risk of fire
or explosion. Never use gaso-
line, naphtha, paint thinners, al-
cohol, or other highly flammable
fuels.

Do not use heavy fuels such as No. 2 fuel oil
or No. 2 Diesel. Using heavy fuels will
result in:

clogged fuel filter and nozzle

carbon build up on spark plug

the need of non-toxic anti-icer in
fuel during very cold weather

IMPORTANT:

Use a KEROSENE ONLY

storage container. Be sure storage container
is clean. Foreign matter such as rust, dirt, or
water will cause the flame-out control to
shut down heater. Foreign matter may also
require you to clean fuel system often.

Advertising